Representative Image

Bohlender b.safe Waste Cap S60 Electronic Fill-Level Control 3x UNF1/4", 1x GL14

Brand:Bohlender

Capillary connections

No. of blind plugs

No. of fittings

No. of olives

Specifications

Compare models
HS Code #
39235090
Capillary connections
3
Connection for exhaust filter
1
No. of blind plugs
2
No. of fittings
3 x 1,6/ 2,2/ 3,2 mm
No. of olives
0
Thread
S 60
UNSPSC
41115700

R 13,307.80

Inc. VAT

Available soon

Product description

The Bohlender b.safe Waste Cap S60 Electronic Fill-Level Control is designed for precise waste management in laboratory settings. Featuring a durable S60 thread, this screw cap includes three UNF 1/4"" fittings and one GL14 connection, offering secure and reliable connections for waste control systems. It comes with a freely movable PTFE insert for connecting capillaries with outer diameters of 1.6 mm, 2.2 mm, or 3.2 mm, as well as hose olives compatible with tubing having inner diameters of 5.5 to 8 mm. The integrated electronic fill-level monitoring ensures accurate tracking of waste levels, supported by a red indicator pin for easy visual monitoring. Additionally, the GL14 thread allows for optional attachment of a b.safe exhaust air filter (not included). The Waste Cap includes a permanently mounted 400 mm cable for connection to the b.safe display for fill-level control, and optionally, a grounding connection can be added with a separately ordered grounding cable.

Key Features:

  • Brand: Bohlender
  • Material: High-quality PTFE for durability and chemical resistance
  • Connection Type: 3x UNF 1/4"", 1x GL14
  • Application: Ideal for laboratories requiring efficient and controlled waste management
  • Includes: Fittings, blind plugs, and a hose olive (NPT 1/8"")
  • Additional Features: Freely movable PTFE insert, permanently mounted 400 mm cable for b.safe display connection, red indicator pin for visual fill-level monitoring, optional grounding connection (grounding cable not included)

Scope of Supply:

  • Fittings (UNF 1/4“)
  • Blind fittings (UNF 1/4“)
  • Hose olive (NPT 1/8")

Ensure optimal waste management with this reliable and precise electronic fill-level control waste cap, ideal for lab environments that require high safety standards.

Downloads

Accessories

Exhaust Filter, PP

ProductMaterialFilter sizeMfr#Part#AvailabilityPrice
PPSM 506-016.313 839In stockR 3,617.90
PPMM 506-026.313 840In stockR 4,705.80
PPLM 506-036.313 841In stockR 6,021.40

Hose connectors for Waste Caps

ProductMaterialLengthMfr#Part#AvailabilityPrice
PP45 mmM 503-014.681 618R 480.70
PTFE45 mmM 503-054.681 619R 910.80
PP30 mmM 503-084.681 620R 455.40
PP32 mmM 503-094.681 621R 379.50
PP23 mmM 503-104.681 622R 379.50
PP26 mmM 503-114.681 623R 379.50
PP26 mmM 503-124.681 624R 379.50
PP30 mmM 503-134.681 625R 379.50
PP36 mmM 503-144.681 626R 379.50
PTFE45 mmM 503-154.681 627R 961.40
PP40 mmM 503-164.681 628R 404.80
PP48 mmM 513-014.681 643R 379.50
PP41 mmM 513-024.681 644R 379.50
PP30 mmM 518-014.681 647R 430.10

Compare similar models

b.safe Waste Cap S60 Electronic Fill-Level Control 3x UNF1/4", 1x GL14

Manufacturer P/N

M 206-41

Part Number

4.681 571

Manufacturer

Bohlender

Capillary connections

3

b.safe Waste Cap S60 Electronic Fill-Level Control 2x UNF1/4", 1x GL14, 1x NPT1/8"

Manufacturer P/N

M 206-42

Part Number

4.681 572

Manufacturer

Bohlender

Capillary connections

2

More items to explore

b.safe Waste Caps S 60, PP, with electronic fill level control and grounding connection

ProductMaterialCapillary connectionsMfr#Part#AvailabilityPrice
PP3M 206-604.681 574R 13,839.10
PP2M 206-614.681 575R 13,915.00

Frequently asked questions

It is designed for precise waste management in laboratory settings. Featuring a durable S60 thread, this screw cap includes three UNF 1/4" fittings and one GL14 connection, offering secure and reliable connections for waste control systems. It comes with a freely movable PTFE insert for connecting capillaries with outer diameters of 1.6 mm, 2.2 mm, or 3.2 mm, as well as hose olives compatible with tubing having inner diameters of 5.5 to 8 mm. The integrated electronic fill-level monitoring ensures accurate tracking of waste levels, supported by a red indicator pin for easy visual monitoring. Additionally, the GL14 thread allows for optional attachment of a b.safe exhaust air filter (not included). The Waste Cap includes a permanently mounted 400 mm cable for connection to the b.safe display for fill-level control, and optionally, a grounding connection can be added with a separately ordered grounding cable.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

14 mins read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story