Representative Image

KEFO Waste SafetyCap (DIN60/61), With 5 x Standard Ports

Brand:KEFO

Capillary connections

No. of fittings

Thread

No. of olives

No. of blind plugs

Specifications

Compare models
Capillary connections
5
Material
PTFE
No. of blind plugs
4
No. of fittings
5 x 2,3 ... 3,2 mm, 4 x 1,6 mm
No. of olives
4 x 7 ... 9 mm
Thread
DIN 60/61
UNSPSC
41115700

R 4,326.30

Inc. VAT

Supplier Stock: 2
Estimated shipping time from Germany : 6-8 weeks

Product description

The KEFO Waste SafetyCap (DIN60/61), With 5 x Standard Ports is designed for collecting liquid HPLC waste while helping reduce exposure to hazardous solvent vapours. The activated carbon in the exhaust filter binds hazardous vapours, and replacement of the exhaust filter after 6 months is recommended. Both capillaries and hose barbs can be inserted into the capillary connections for flexible laboratory waste handling.

Key Features:

  • Brand: KEFO
  • Product Type: Waste SafetyCap
  • Connection: DIN60/61
  • Ports: 5 x standard ports
  • Application: Ideal for collecting liquid HPLC waste
  • Filter: Activated carbon exhaust filter binds hazardous solvent vapours
  • Replacement: Exhaust filter replacement recommended after 6 months
  • Compatibility: Capillaries and hose barbs can be inserted into the capillary connections
  • Materials: Caps and fittings made of PP, body and hose barbs made of PTFE
  • Special Features: With timestrip sticker
  • Note: Exhaust filter to be ordered separately

This KEFO Waste SafetyCap is suitable for laboratories requiring a secure cap solution for HPLC waste collection and solvent vapour management.

Accessories

Exhaust filters for Waste SafetyCaps

ProductShelf lifeThreadMfr#Part#AvailabilityPrice
3 monthsGL 14SC000131.2*LE4.684 241R 3,187.80
6 monthsGL 14SC000132.2*LE4.684 242R 5,262.40

Fittings for Eluent SafetyCaps / Waste SafetyCaps

ProductMaterialColourMfr#Part#AvailabilityPrice
PPBlueSC000140.1*LE4.684 223R 1,619.20
PPGreenSC000139.10*LE4.684 221R 1,619.20
PPPurpleSC000138.10*LE4.684 220R 1,416.80

Compare similar models

Waste SafetyCap (DIN60/61) with 5x Standard ports

Manufacturer P/N

SC000149.1*LE

Part Number

4.684 236

Manufacturer

KEFO

Capillary connections

5

Waste SafetyCap (GL45/DIN45) with 3x Standard ports incl. 3xPP fitting

Manufacturer P/N

SC000129.1*LE

Part Number

4.684 227

Manufacturer

KEFO

Capillary connections

3

Waste SafetyCap (GL45/DIN45) with 3x Standard ports iocl. 2xPP fitting+1xHoseBarb

Manufacturer P/N

SC000130.2*LE

Part Number

4.684 228

Manufacturer

KEFO

Capillary connections

3

Waste SafetyCap (GL45/DIN45) with 2x Standard ports

Manufacturer P/N

SC000144.1*LE

Part Number

4.684 229

Manufacturer

KEFO

Capillary connections

2

Waste SafetyCap (S55/DIN51) with 3x Standard ports
Available soon
KEFO Waste SafetyCap (S55/DIN51), with 3x Standard ports

R 3,567.30

Inc. VAT

Manufacturer P/N

SC000137.1*LE

Part Number

4.684 230

Manufacturer

KEFO

Capillary connections

3

Waste SafetyCap (S55/DIN51) with 4x Standard ports
Available soon
KEFO Waste SafetyCap (S55/DIN51), with 4x Standard ports

R 2,909.50

Inc. VAT

Manufacturer P/N

SC000145.1*LE

Part Number

4.684 231

Manufacturer

KEFO

Capillary connections

4

Waste SafetyCap (DIN60/61) with 3x Standard ports
Available soon
KEFO Waste SafetyCap (DIN60/61), with 3x Standard ports

R 3,693.80

Inc. VAT

Manufacturer P/N

SC000147.1*LE

Part Number

4.684 234

Manufacturer

KEFO

Capillary connections

3

Waste SafetyCap (DIN60/61) with 4x Standard ports
Available soon
KEFO Waste SafetyCap (DIN60/61), with 4x Standard ports

R 3,693.80

Inc. VAT

Manufacturer P/N

SC000148.1*LE

Part Number

4.684 235

Manufacturer

KEFO

Capillary connections

4

Frequently asked questions

It is designed for collecting liquid HPLC waste while helping reduce exposure to hazardous solvent vapours. The activated carbon in the exhaust filter binds hazardous vapours, and replacement of the exhaust filter after 6 months is recommended. Both capillaries and hose barbs can be inserted into the capillary connections for flexible laboratory waste handling.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

14 mins read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story

R 4,326.30

Inc. VAT