Representative Image

Ludwig Schneider Precision ASTM Hydrometer, Type S502HL-14, -20 to +65°C in 1°C, 700 to 750 in 0,5 kg/m³, 380 mm

Max. measured value

Measured range

Min. measured value

Specifications

Compare models
Colour filling
Blue
Division
0.5
Length
380 mm
Max. measured value
750 kg/m³
Max. temperature
65 °C
Measured range
700 ... 750 kg/m³
Min. measured value
700 kg/m³
Min. temperature
-20 °C
Reference temperature
15 °C
Standard
ASTM E2995-14

R 4,174.50

Inc. VAT

Available soon

Product description

The Ludwig Schneider Precision ASTM Hydrometer, Type S502HL-14, is designed for the determination of density for mineral oil in accordance with ASTM E2995-14. This precision hydrometer includes a mercury-free thermometer with a measuring range of -20 to +65°C in 1°C divisions, along with a density range of 700 to 750 in 0,5 kg/m³, making it suitable for accurate laboratory testing and petroleum applications.

Key Features:

  • Brand: Ludwig Schneider
  • Type: Precision ASTM hydrometer, Type S502HL-14
  • Standard: According to ASTM E2995-14
  • Density Range: 700 to 750 in 0,5 kg/m³
  • Density Error Limit: ± 0,5 kg/m³
  • Thermometer Range: -20 to +65°C in 1°C
  • Thermometer Error Limit: ± 1°C
  • Filling: Blue, environmentally friendly thermometer filling
  • Length: 380 mm
  • Application: Suitable for density determination of mineral oil
  • Packaging: Packed in plastic tubes for breakage protection
  • Calibration: Works calibration available on request

This Ludwig Schneider precision ASTM hydrometer is a dependable choice for laboratories requiring compliant density measurement, integrated temperature reference, and safe mercury-free operation for mineral oil analysis.

Compare similar models

Precision-ASTM-hydrometer type S502HL-14 -20...+65°C in 1°C, 700-750 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222113S

Part Number

6.267 134

Manufacturer

Ludwig Schneider

Max. measured value

750 kg/m³

Precision-ASTM-hydrometer type S500HL-14 -20...+65°C in 1°C, 600-650 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222111S

Part Number

6.267 132

Manufacturer

Ludwig Schneider

Max. measured value

650 kg/m³

Precision-ASTM-hydrometer type S501HL-14 -20...+65°C in 1°C, 650-700 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222112S

Part Number

6.267 133

Manufacturer

Ludwig Schneider

Max. measured value

700 kg/m³

Precision-ASTM-hydrometer type S503HL-14 -20...+65°C in 1°C, 750-800 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222114S

Part Number

6.267 135

Manufacturer

Ludwig Schneider

Max. measured value

800 kg/m³

Precision-ASTM-hydrometer type S504HL-14 -20...+65°C in 1°C, 800-850 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222115S

Part Number

6.267 136

Manufacturer

Ludwig Schneider

Max. measured value

850 kg/m³

Precision-ASTM-hydrometer type S505HL-14 -20...+65°C in 1°C, 850-900 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222116S

Part Number

6.267 137

Manufacturer

Ludwig Schneider

Max. measured value

900 kg/m³

Precision-ASTM-hydrometer type S506HL-14 -20...+65°C in 1°C, 900-950 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222117S

Part Number

6.267 138

Manufacturer

Ludwig Schneider

Max. measured value

950 kg/m³

Precision-ASTM-hydrometer type S507HL-14 -20...+65°C in 1°C, 900-1000 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222118S

Part Number

6.267 139

Manufacturer

Ludwig Schneider

Max. measured value

1000 kg/m³

Precision-ASTM-hydrometer type S508HL-14 -20...+65°C in 1°C, 1000-1050 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222119S

Part Number

6.267 140

Manufacturer

Ludwig Schneider

Max. measured value

1050 kg/m³

Precision-ASTM-hydrometer type S509HL-14 -20...+65°C in 1°C, 1050-1100 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222120S

Part Number

6.267 141

Manufacturer

Ludwig Schneider

Max. measured value

1100 kg/m³

Precision-ASTM-thermometer Type S510HL-14 -20...+65°C in 1°C, 775-825 in 0,5 kg/m³, 380 mm

Manufacturer P/N

3222345S

Part Number

6.267 142

Manufacturer

Ludwig Schneider

Max. measured value

825 kg/m³

Frequently asked questions

It is designed for the determination of density for mineral oil in accordance with ASTM E2995-14. This precision hydrometer includes a mercury-free thermometer with a measuring range of -20 to +65°C in 1°C divisions, along with a density range of 700 to 750 in 0,5 kg/m³, making it suitable for accurate laboratory testing and petroleum applications.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

1 min read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

1 min read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

1 min read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story

R 4,174.50

Inc. VAT