Representative Image

Ludwig Schneider Pt100 Transition-Sleeve Sensor with Handle – Class A, −50 °C to +200 °C, 150 mm, Ø 3 mm, 3 m Cable

Cable length

Ø

Dimensions (ØxL)

Length

Max. temperature

Min. temperature

Temperature

Specifications

Compare models
Accuracy class
A
Cable length
3 m
Ø
3 mm
Dimensions (ØxL)
3 x 150 mm
Length
150 mm
Material
Stainless steel
Max. temperature
200 °C
Min. temperature
-50 °C
Resolution
0.01 °C
Temperature
-50 ... 200 °C

R 6,400.90

Inc. VAT

Available soon

Product description

The Ludwig Schneider Pt100 Transition-Sleeve Sensor with handle provides exceptional precision for temperature measurement in laboratory and industrial settings. Engineered to Class A specifications, this sensor operates accurately across a temperature range of −50 °C to +200 °C. It includes a 150 mm-long, Ø 3 mm stainless steel probe integrated into a transition sleeve design, allowing for easy insertion into thermowells or protective pipes. The 3 metre cable ensures flexible placement and seamless connectivity to monitoring instruments.

Key Features:

  • Brand: Ludwig Schneider
  • Sensor Type: Pt100 (Platinum Resistance Thermometer), Class A accuracy
  • Temperature Range: −50 °C to +200 °C
  • Nominal Length: 150 mm
  • Probe Diameter: Ø 3 mm
  • Cable Length: 3 m
  • Design: Transition-sleeve with ergonomic handle—ideal for thermowell or fitting use
  • Applications: Labs, process control, calibration setups, and custom installation needs

Designed for accuracy, versatility, and safety, this Pt100 sensor offers seamless integration with control systems and robust performance in demanding environments.

Compare similar models

Pt100 transition sleeve with handle Class A, application range -50 to+200 ° C Nominal length 150mm,

Manufacturer P/N

70134

Part Number

6.273 646

Manufacturer

Ludwig Schneider

Cable length

3 m

Pt100 transition sleeve with handle Class A, application range -50 to+200 ° C Nominal length 150mm,

Manufacturer P/N

70128

Part Number

6.273 647

Manufacturer

Ludwig Schneider

Cable length

3 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 400mm,

Manufacturer P/N

70130

Part Number

6.273 449

Manufacturer

Ludwig Schneider

Cable length

2 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 300mm,

Manufacturer P/N

70137

Part Number

6.273 648

Manufacturer

Ludwig Schneider

Cable length

3 m

Pt100 transition sleeve with handle Class A, application range -50 to+200 ° C Nominal length 150mm,

Manufacturer P/N

70133

Part Number

6.273 444

Manufacturer

Ludwig Schneider

Cable length

2 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 400mm,

Manufacturer P/N

70132

Part Number

6.273 672

Manufacturer

Ludwig Schneider

Cable length

5 m

Pt100 transition sleeve with handle Class A, application range -50 to+200 ° C Nominal length 150mm,

Manufacturer P/N

70135

Part Number

6.273 667

Manufacturer

Ludwig Schneider

Cable length

5 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 300mm,

Manufacturer P/N

70126

Part Number

6.273 670

Manufacturer

Ludwig Schneider

Cable length

5 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 300mm,

Manufacturer P/N

70113

Part Number

6.273 649

Manufacturer

Ludwig Schneider

Cable length

3 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 400mm,

Manufacturer P/N

70131

Part Number

6.273 651

Manufacturer

Ludwig Schneider

Cable length

3 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 400mm,

Manufacturer P/N

70139

Part Number

6.273 448

Manufacturer

Ludwig Schneider

Cable length

2 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 300mm,

Manufacturer P/N

70112

Part Number

6.273 447

Manufacturer

Ludwig Schneider

Cable length

2 m

Pt100 transition sleeve with handle Class A, application range -50 to+200 ° C Nominal length 150mm,

Manufacturer P/N

70129

Part Number

6.273 668

Manufacturer

Ludwig Schneider

Cable length

5 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 300mm,

Manufacturer P/N

70138

Part Number

6.273 669

Manufacturer

Ludwig Schneider

Cable length

5 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 400mm,

Manufacturer P/N

70140

Part Number

6.273 650

Manufacturer

Ludwig Schneider

Cable length

3 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 400mm,

Manufacturer P/N

70141

Part Number

6.273 671

Manufacturer

Ludwig Schneider

Cable length

5 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 300mm,

Manufacturer P/N

70136

Part Number

6.273 446

Manufacturer

Ludwig Schneider

Cable length

2 m

Pt100 transition sleeve with handle Class A, application range -50 to+200 ° C Nominal length 150mm,

Manufacturer P/N

70127

Part Number

6.273 445

Manufacturer

Ludwig Schneider

Cable length

2 m

Frequently asked questions

It provides exceptional precision for temperature measurement in laboratory and industrial settings. Engineered to Class A specifications, this sensor operates accurately across a temperature range of −50 °C to +200 °C. It includes a 150 mm-long, Ø 3 mm stainless steel probe integrated into a transition sleeve design, allowing for easy insertion into thermowells or protective pipes. The 3 metre cable ensures flexible placement and seamless connectivity to monitoring instruments.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

14 mins read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story

R 6,400.90

Inc. VAT