Macherey-Nagel Capillary Column Optima 1701, 0.32 mm ID, 1 µm Film Thickness, 30 m Length

Film thickness

Int. Ø

Length

Specifications

Compare models
HS Code #
90279000
Film thickness
1.00 µm
Int. Ø
0.32 mm
Length
30 m
Material column
Quartz glass
Max. temperature programme
300 °C
Polarity
Mid-polar
Temperature max. isotherm
280 °C
UNSPSC
41115710
USP listing
G46

R 22 491,70

Inc. VAT

Available soon

Product description

The Macherey-Nagel Capillary Column Optima 1701 is a high-performance column designed for gas chromatography (GC) applications. Featuring a 0.32 mm internal diameter (ID) and a 1 µm film thickness, this column ensures superior separation and resolution of volatile compounds. The 30 m length is ideal for a wide range of analytical applications, including environmental, pharmaceutical, and chemical testing. Built to withstand high temperatures and aggressive solvents, the Macherey-Nagel Optima 1701 column offers excellent durability and reliability, making it a perfect choice for precision GC analysis.

Key Features:

  • Brand: Macherey-Nagel
  • Type: Capillary Column Optima 1701
  • Internal Diameter: 0.32 mm for improved resolution
  • Film Thickness: 1 µm for high-efficiency separation
  • Length: 30 m, ideal for diverse GC applications
  • Applications: Suitable for environmental, pharmaceutical, and chemical analysis

The Macherey-Nagel Capillary Column Optima 1701 is designed to provide consistent, reliable performance in a variety of GC applications, offering enhanced separation and reproducibility.

Compare similar models

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 1 µm length: 30 m

Manufacturer P/N

726929.30

Part Number

4.003 269

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 0.5 µm length: 30 m

Manufacturer P/N

726064.30

Part Number

4.003 039

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.5 µm length: 25 m

Manufacturer P/N

726320.25

Part Number

4.003 107

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.25 µm length: 30 m

Manufacturer P/N

726318.30

Part Number

4.003 104

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.35 µm length: 25 m

Manufacturer P/N

726824.25

Part Number

4.003 222

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.25 µm length: 25 m

Manufacturer P/N

726318.25

Part Number

4.003 103

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.25 µm length: 60 m

Manufacturer P/N

726318.60

Part Number

4.003 106

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 0.25 µm length: 30 m

Manufacturer P/N

726058.30

Part Number

4.003 036

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.5 µm length: 30 m

Manufacturer P/N

726320.30

Part Number

4.003 108

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.35 µm length: 60 m

Manufacturer P/N

726824.60

Part Number

4.003 225

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 1 µm length: 25 m

Manufacturer P/N

726929.25

Part Number

4.003 268

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.5 µm length: 50 m

Manufacturer P/N

726320.50

Part Number

4.003 109

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.53 mm, film thickness: 2 µm length: 25 m

Manufacturer P/N

726735.25

Part Number

4.003 178

Manufacturer

Macherey-Nagel

Film thickness

2.00 µm

Capillary column OPTIMA-1701 ID: 0.53 mm, film thickness: 2 µm length: 50 m

Manufacturer P/N

726735.50

Part Number

4.003 180

Manufacturer

Macherey-Nagel

Film thickness

2.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.35 µm length: 50 m

Manufacturer P/N

726824.50

Part Number

4.003 224

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 0.25 µm length: 25 m

Manufacturer P/N

726058.25

Part Number

4.003 035

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 1 µm length: 30 m

Manufacturer P/N

726965.30

Part Number

4.003 272

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.50 µm length 60 m

Manufacturer P/N

726320.60

Part Number

7.088 327

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 0.25 µm length: 50 m

Manufacturer P/N

726058.50

Part Number

4.003 037

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 0.5 µm length: 60 m

Manufacturer P/N

726064.60

Part Number

4.003 040

Manufacturer

Macherey-Nagel

Film thickness

0.50 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.25 µm length: 50 m

Manufacturer P/N

726318.50

Part Number

4.003 105

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.25 mm, film thickness: 0.25 µm length: 60 m

Manufacturer P/N

726058.60

Part Number

4.003 038

Manufacturer

Macherey-Nagel

Film thickness

0.25 µm

Capillary column OPTIMA-1701 ID: 0.53 mm, film thickness: 1 µm length: 30 m

Manufacturer P/N

726545.30

Part Number

4.003 173

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 1 µm length: 50 m

Manufacturer P/N

726929.50

Part Number

4.003 270

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 0.35 µm length: 30 m

Manufacturer P/N

726824.30

Part Number

4.003 223

Manufacturer

Macherey-Nagel

Film thickness

0.35 µm

Capillary column OPTIMA-1701 ID: 0.53 mm, film thickness: 1 µm length: 25 m

Manufacturer P/N

726545.25

Part Number

4.003 172

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.32 mm, film thickness: 1 µm length: 60 m

Manufacturer P/N

726929.60

Part Number

4.003 271

Manufacturer

Macherey-Nagel

Film thickness

1.00 µm

Capillary column OPTIMA-1701 ID: 0.53 mm, film thickness: 2 µm length: 30 m

Manufacturer P/N

726735.30

Part Number

4.003 179

Manufacturer

Macherey-Nagel

Film thickness

2.00 µm

Frequently asked questions

It is a high-performance column designed for gas chromatography (GC) applications. Featuring a 0.32 mm internal diameter (ID) and a 1 µm film thickness, this column ensures superior separation and resolution of volatile compounds. The 30 m length is ideal for a wide range of analytical applications, including environmental, pharmaceutical, and chemical testing. Built to withstand high temperatures and aggressive solvents, the Macherey-Nagel Optima 1701 column offers excellent durability and reliability, making it a perfect choice for precision GC analysis.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

14 mins read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story