Representative Image

Memmert Climate Cabinet ICH750 -10...+60°C, 749 Ltr

Brand:Memmert

Depth int.

Ext. dim. (WxDxH)

Ext. depth

Ext. height

Ext. width

Height int.

Int. Dim. (WxDxH)

Int. width

Max. no. of inserts

Nominal capacity

Type

Weight

Specifications

Compare models
HS Code #
84193900
Depth int.
600 mm
Ext. dim. (WxDxH)
1,224 x 785 x 1,950 mm
Ext. depth
785 mm
Ext. height
1950 mm
Ext. width
1224 mm
Power supply frequency
50/60 Hz
Height int.
1200 mm
Int. Dim. (WxDxH)
1,040 x 600 x 1,200 mm
Int. width
1040 mm
Material inserts
Stainless steel

R 625,188.30

Inc. VAT

Available soon

Product description

The Memmert Climate Cabinet ICH750 is engineered for precise stability testing in pharmaceutical, cosmetic, and food industries. With a spacious 749-litre capacity and a temperature range from -10°C to +60°C, it ensures unparalleled temperature and humidity uniformity, meeting ICH, WHO, EMA, ASEAN, GMP, GLP, and GCCP guidelines.

Key Features:

  • Brand: Memmert
  • Model: ICH750
  • Temperature Range: -10°C to +60°C without humidity; +10°C to +60°C with humidity
  • Humidity Range: 10% to 80% RH
  • Capacity: 749 litres
  • Air Circulation: Forced air circulation for uniform temperature and humidity distribution
  • Display: TwinDisplay for precise monitoring and control
  • Applications: Ideal for stability testing in pharmaceutical, cosmetic, and food industries

This climate cabinet is essential for laboratories requiring precise environmental conditions for stability testing.

Accessories

Options and accessories for constant climate chamber HPP

ProductTypeDescriptionMfr#Part#AvailabilityPrice
FDAQ1FDA conform software AtmoCONTROL meets the requirements for the use of electronically stored data sets and electronic signatures acc. Regulation 21 CFR Part 11 of the US Food and Drug AdministrationFDAQ16.266 309R 26,640.90
D00137IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature, humidity and light value. 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customerD00137 HPP6.267 333R 153,318.00
D00136IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature and humidity value. 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customerD00136 HPP6.266 308R 121,009.90
D00124IQ document with works test data for chamberD00124 HPP6.266 307R 18,140.10
T7Light module cold white 6.500 kelvinT7 HPP/IPP/2609.868 025R 110,358.60
T8Light module cold white 6.500 kelvin + warm white 2.700 kelvinT8 HPP/IPP/410/79.868 029R 122,199.00
T7Light module cold white 6.500 kelvinT7 HPP/IPP/7509.868 026R 122,199.00
T7Light module cold white 6.500 kelvinT7 HPP/IPP/1109.868 024R 78,910.70
T8Light module cold white 6.500 kelvin + warm white 2.700 kelvinT8 HPP/IPP/2609.868 028R 110,358.60
T8Light module cold white 6.500 kelvin + warm white 2.700 kelvinT8 HPP/IPP/1109.868 027R 78,910.70

Compare similar models

Climate cabinet ICH750 -10...-60°C, 749 ltr.
Available soon
Memmert Climate Cabinet ICH750 -10...+60°C, 749 Ltr

R 625,188.30

Inc. VAT

Manufacturer P/N

ICH750

Part Number

9.538 020

Manufacturer

Memmert

Depth int.

600 mm

Climate cabinet ICH260 -10...-60°C, 256 ltr.
Available soon
Memmert Climate Cabinet ICH260 -10...+60°C, 256 Ltr

R 457,854.10

Inc. VAT

Manufacturer P/N

ICH260

Part Number

9.538 019

Manufacturer

Memmert

Depth int.

500 mm

Climate cabinet ICH110 -10...-60°C, 108 ltr.
Available soon
Memmert Climate Cabinet ICH110 -10...+60°C, 108 Ltr

R 349,114.70

Inc. VAT

Manufacturer P/N

ICH110

Part Number

9.538 018

Manufacturer

Memmert

Depth int.

400 mm

Frequently asked questions

It is engineered for precise stability testing in pharmaceutical, cosmetic, and food industries. With a spacious 749-litre capacity and a temperature range from -10°C to +60°C, it ensures unparalleled temperature and humidity uniformity, meeting ICH, WHO, EMA, ASEAN, GMP, GLP, and GCCP guidelines.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

14 mins read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story