Representative Image

Memmert UF75plus, Universal Cabinet +20…+300°C, 74 Ltr, Laboured Air Circulation with TwinDisplay

Brand:Memmert

Depth int.

Ext. dim. (WxDxH)

Ext. depth

Ext. height

Ext. width

Height int.

Int. Dim. (WxDxH)

Int. width

Max. no. of inserts

Max. voltage

Nominal capacity

Power supply

Rated capacity

Temperature

Type

Weight

Specifications

Compare models
Depth int.
330 mm
Ext. dim. (WxDxH)
585 x 514 x 944 mm
Ext. depth
514 mm
Ext. height
944 mm
Ext. width
585 mm
Power supply frequency
50/60 Hz
Height int.
560 mm
Int. Dim. (WxDxH)
400 x 330 x 560 mm
Int. width
400 mm
Material interior
Stainless steel 1.4301

R 100,997.60

Inc. VAT

Available soon

Product description

The Memmert UF75plus Universal Cabinet offers precise temperature control from +20°C to +300°C within a 74-litre chamber. Designed for laboratory applications requiring uniform temperature distribution, it features laboured air circulation and a TwinDisplay control system for intuitive operation.

Key Features:

  • Brand: Memmert
  • Model: UF75plus
  • Temperature Range: +20°C to +300°C
  • Capacity: 74 litres
  • Air Circulation: Laboured air circulation for even temperature distribution
  • Control System: TwinDisplay with two high-definition TFT-color displays
  • Applications: Suitable for drying, heating, aging, burn-in, and hardening processes in research, science, industry, and quality assurance

This universal cabinet is ideal for laboratories requiring precise temperature control and uniform conditions for sensitive experiments.

Accessories

Special equipment for Universal ovens and Incubators

ProductTypeDescriptionMfr#Part#AvailabilityPrice
E06189Ethernet connection cable 5 m for computer interfaceE061899.867 758In stockR 1,366.20
B33170USB User ID Stick (only for units with TwinDISPLAY)B331706.257 480R 8,703.20
E06192USB Ethernet adapterE061929.867 717R 2,428.80
D00125IQ/OQ document, with device-specific works test data for one free-selectable temperature value, incl. temperature distribution survey at Memmert for 9 measuring points to DIN 12880:2007-05 for model 30, PQ check list as support for validation by cuD001259.867 756R 59,429.70
D00127IQ/OQ document, with device-specific works test data for one free-selectable temperature value, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05 for model 55 - 1060, PQ check list as support for validatiD001279.867 757R 77,721.60

Glass door for Universal ovens

ProductTypeUNSPSCMfr#Part#AvailabilityPrice
B0 75041104512B0 7509.868 135R 47,817.00
B0 3041104512B0 306.257 761R 11,663.30
B0 11041104512B0 1106.259 301R 14,876.40
B0 7541104512B0 756.263 335R 13,839.10
B0 16041104512B0 1609.868 132R 18,469.00
B0 5541104512B0 559.868 131R 12,776.50
B0 45041104512B0 4509.868 134R 36,406.70
B0 26041104512B0 2609.868 133R 29,019.10
B0 106041104512B0 10609.868 136R 47,817.00

Compare similar models

Universal cabinet UF75plus +20...+300°C, 74 ltr. laboured air circulation, with TwinDISPLAY

Manufacturer P/N

UF75PLUS

Part Number

9.869 707

Manufacturer

Memmert

Depth int.

330 mm

Universal cabinet UF30plus +20...+300°C, 32 Ltr. laboured air circulation, with TwinDISPLAY

Manufacturer P/N

UF30PLUS

Part Number

9.869 705

Manufacturer

Memmert

Depth int.

250 mm

Universal cabinet UF55plus +20...+300°C, 53 ltr. laboured air circulation, with TwinDISPLAY

Manufacturer P/N

UF55PLUS

Part Number

9.869 706

Manufacturer

Memmert

Depth int.

330 mm

Universal cabinet UF110plus +20...+300°C, 108 ltr. laboured air circulation, with TwinDISPLAY

Manufacturer P/N

UF110PLUS

Part Number

9.869 708

Manufacturer

Memmert

Depth int.

400 mm

Universal cabinet UF160plus +20...+300°C, 161 ltr. laboured air circulation, with TwinDISPLAY

Manufacturer P/N

UF160PLUS

Part Number

9.869 709

Manufacturer

Memmert

Depth int.

400 mm

Universal cabinet UF260plus +20...+300°C, 256 ltr. laboured air circulation, with TwinDISPLAY

Manufacturer P/N

UF260PLUS

Part Number

9.869 710

Manufacturer

Memmert

Depth int.

500 mm

Universal cabinet UF750plus +20...+300°C, 749 ltr. laboured air circulation, with TwinDISPLAY

Manufacturer P/N

UF750PLUS

Part Number

9.869 712

Manufacturer

Memmert

Depth int.

600 mm

Universal cabinet UF450plus +20...+300°C, 449 ltr. laboured air circulation, with TwinDISPLAY

Manufacturer P/N

UF450PLUS

Part Number

9.869 711

Manufacturer

Memmert

Depth int.

600 mm

Universal cabinet UF1060plus +20...+300°C, 1060 ltr. forced circulation air, with TwinDISPLAY

Manufacturer P/N

UF1060PLUS

Part Number

9.869 713

Manufacturer

Memmert

Depth int.

850 mm

Frequently asked questions

It offers precise temperature control from +20°C to +300°C within a 74-litre chamber. Designed for laboratory applications requiring uniform temperature distribution, it features laboured air circulation and a TwinDisplay control system for intuitive operation.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

1 min read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

1 min read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

1 min read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story

R 100,997.60

Inc. VAT