SCAT SafetyCap I, V2.0, GL45 preparative, 1x PTFE-fitting 4.76 mm OD + air valve

Brand:SCAT

Capillary connections

No. of fittings

Specifications

Compare models
HS Code #
39269097
Capillary connections
1
Material
PPS/PTFE
No. of fittings
3 x 4,76 mm
Thread
GL 45
UNSPSC
41115700

R 4,554.00

Inc. VAT

Available soon

Product description

The SCAT SafetyCap I, V2.0, GL45 preparative is designed for secure solvent supply in HPLC systems. Featuring a single PTFE fitting with a 4.76 mm outer diameter, it ensures a tight and chemically resistant connection. The integrated air valve facilitates pressure equalization, maintaining system integrity during solvent withdrawal. Constructed from PPS/PTFE materials, this cap offers excellent chemical resistance and durability, making it ideal for laboratory environments.

Key Features:

  • Brand: SCAT
  • Thread Size: GL45
  • Fittings: 1x PTFE fitting, 4.76 mm OD
  • Material: PPS/PTFE for high chemical resistance
  • Integrated Components: Air valve and change indicator
  • Application: Suitable for preparative HPLC solvent supply

Scope of Supply:

  • Safety Cap
  • Air valve
  • Change indicator
  • PFA fittings
  • PTFE fitting
  • Labelling field

This SCAT SafetyCap I ensures safe and efficient solvent handling, contributing to a secure laboratory workflow.

Accessories

Thread adapters for SafetyCaps / SafetyWasteCaps, female / male thread

ProductMaterialColourMfr#Part#AvailabilityPrice
PPColourless1070994.005 483In stockR 2,277.00
PTFEWhite1079929.139 882R 2,960.10
PTFEWhite1079919.139 883R 2,960.10
PTFEWhite1079934.005 639R 2,960.10
PPColourless1079954.005 641R 2,277.00
PPColourless1079964.005 642R 2,277.00
PPColourless1079944.005 640R 2,277.00
PPColourless1070934.005 477R 2,277.00
PPColourless1070794.005 463R 4,098.60
PPColourless1070904.005 474R 2,277.00
PPColourless1070284.005 433R 2,277.00
PTFEWhite1170304.005 789R 2,960.10
PPColourless1070954.005 479R 2,277.00
PPColourless1070924.005 476R 2,277.00
PTFEWhite1070724.005 456R 4,098.60
PPColourless1070944.005 478R 1,366.20
PPColourless1070864.005 470R 2,277.00
PPColourless1070974.005 481R 2,960.10
PPColourless1070744.005 458R 3,187.80
PPColourless1070854.005 469R 2,277.00
PPColourless1070894.005 473R 2,277.00
PPColourless1070914.005 475R 1,821.60
PPColourless1070964.005 480R 2,277.00
PPColourless1070714.005 950R 2,277.00
PPColourless1070844.005 468R 2,960.10

Air valves Generation 2.0 for SafetyCaps

ProductColourShelf lifeMfr#Part#AvailabilityPrice
Red6 months3170104.669 375In stockR 1,138.50
Red6 months3970504.669 377In stockR 33,775.50
Red6 months3970104.669 376In stockR 8,020.10
Red6 months3970086.318 227In stockR 6,755.10
Red6 months3971004.683 899In stockR 47,285.70

Compare similar models

SafetyCap I, V2.0, GL45 preperative, 1x PTFE-fitting 4,76 mm OD + air valve

Manufacturer P/N

308032

Part Number

9.139 810

Manufacturer

SCAT

Capillary connections

1

SafetyCap II, V2.0, GL45 preparative, 2x PTFE-fitting 4,76 mm OD + air valve

Manufacturer P/N

309032

Part Number

6.316 829

Manufacturer

SCAT

Capillary connections

2

SafetyCap II V2.0 GL45 preparative, 1x PTFE fittings 3.2 mm OD 1x PTFE fitting 6.35 mm O.D. + venting valve

Manufacturer P/N

307009

Part Number

6.313 749

Manufacturer

SCAT

Capillary connections

2

SafetyCap II V2.0 GL45 preparative, 2x PTFE fittings 6.35 mm OD venting valve

Manufacturer P/N

307008

Part Number

6.315 586

Manufacturer

SCAT

Capillary connections

2

SafetyCap III, V2.0, GL45 preparative, 3x PTFE fittings 4,76 mm AD and ventilation valve

Manufacturer P/N

310032

Part Number

6.312 738

Manufacturer

SCAT

Capillary connections

3

SafetyCap I, V2.0, GL45, preperative 1x PTFE-fitting 6,35 mm OD + air valve

Manufacturer P/N

307007

Part Number

6.314 967

Manufacturer

SCAT

Capillary connections

1

Frequently asked questions

It is designed for secure solvent supply in HPLC systems. Featuring a single PTFE fitting with a 4.76 mm outer diameter, it ensures a tight and chemically resistant connection. The integrated air valve facilitates pressure equalization, maintaining system integrity during solvent withdrawal. Constructed from PPS/PTFE materials, this cap offers excellent chemical resistance and durability, making it ideal for laboratory environments.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

14 mins read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story