Representative Image

SCAT SafetyCap VI, V2.0, GL45 with 6x Shut-Off, 6x PFA-fitting 3.2 mm OD + Air Valve

Brand:SCAT

Capillary connections

No. of blind plugs

No. of fittings

No. of stopcocks

Specifications

Compare models
Capillary connections
6
No. of blind plugs
1
No. of fittings
3 x 1,6/ 2,3/ 3,2 mm
No. of stopcocks
1
Thread
GL 45
UNSPSC
41115700

R 8,197.20

Inc. VAT

Available soon

Product description

The SCAT SafetyCap VI, V2.0, GL45 is engineered for secure and efficient solvent supply in laboratory environments. This cap features six PFA fittings compatible with 1.6 mm, 2.3 mm, and 3.2 mm outer diameter tubing, ensuring versatile connectivity for various laboratory setups. The integrated air valve facilitates pressure equalization, maintaining system integrity during solvent withdrawal. Constructed from high-quality PTFE, it offers exceptional chemical resistance, making it suitable for handling aggressive solvents. The cap includes a change indicator and blind plugs for unused ports, enhancing laboratory safety and efficiency.

Key Features:

  • Brand: SCAT
  • Thread Size: GL45
  • Material: PTFE for high chemical resistance
  • Fittings: 6x PFA fittings for 1.6 mm, 2.3 mm, and 3.2 mm OD tubing
  • Integrated Components: Air valve, change indicator, and blind plugs
  • Application: Suitable for solvent supply in HPLC and analytical laboratories

Scope of Supply:

  • Safety Cap
  • Shut-off
  • Air valve
  • Change indicator
  • PFA fittings
  • PFA blind plug
  • Labelling field

The SCAT SafetyCap VI, V2.0, GL45 combines advanced safety features with robust chemical resistance, making it an indispensable tool for laboratories focused on safe, reliable, and efficient solvent handling.



Frequently Asked Questions

1. What is the SCAT SafetyCap VI, V2.0, GL45 with 6x Shut-Off, 6x PFA-fitting 3.2 mm OD + Air Valve used for?

It is engineered for secure and efficient solvent supply in laboratory environments. This cap features six PFA fittings compatible with 1.6 mm, 2.3 mm, and 3.2 mm outer diameter tubing, ensuring versatile connectivity for various laboratory setups. The integrated air valve facilitates pressure equalization, maintaining system integrity during solvent withdrawal. Constructed from high-quality PTFE, it offers exceptional chemical resistance, making it suitable for handling aggressive solvents. The cap includes a change indicator and blind plugs for unused ports, enhancing laboratory safety and efficiency.

2. Is this product suitable for solvent supply in HPLC and analytical laboratories?

Yes. It is designed for solvent supply in HPLC and analytical laboratories, and offers 6x PFA fittings for 1.6 mm, 2.3 mm, and 3.2 mm OD tubing to support this kind of work.

3. What fittings does this product have?

It has 6x PFA fittings for 1.6 mm, 2.3 mm, and 3.2 mm OD tubing.

4. What is this product made from and what features does it include?

It is made from PTFE for high chemical resistance. It also offers GL45, air valve, change indicator, and blind plugs and safety Cap.

Downloads

Accessories

Thread adapters for SafetyCaps / SafetyWasteCaps, female / male thread

ProductMaterialColourMfr#Part#AvailabilityPrice
PPColourless1070994.005 483In stockR 2,277.00
PTFEWhite1079929.139 882R 2,960.10
PTFEWhite1079919.139 883R 2,960.10
PTFEWhite1079934.005 639R 2,960.10
PPColourless1079954.005 641R 2,277.00
PPColourless1079964.005 642R 2,277.00
PPColourless1079944.005 640R 2,277.00
PPColourless1070934.005 477R 2,277.00
PPColourless1070794.005 463R 4,098.60
PPColourless1070904.005 474R 2,277.00
PPColourless1070284.005 433R 2,277.00
PTFEWhite1170304.005 789R 2,960.10
PPColourless1070954.005 479R 2,277.00
PPColourless1070924.005 476R 2,277.00
PTFEWhite1070724.005 456R 4,098.60
PPColourless1070944.005 478R 1,366.20
PPColourless1070864.005 470R 2,277.00
PPColourless1070974.005 481R 2,960.10
PPColourless1070744.005 458R 3,187.80
PPColourless1070854.005 469R 2,277.00
PPColourless1070894.005 473R 2,277.00
PPColourless1070914.005 475R 1,821.60
PPColourless1070964.005 480R 2,277.00
PPColourless1070714.005 950R 2,277.00
PPColourless1070844.005 468R 2,960.10

Air valves Generation 2.0 for SafetyCaps

ProductColourShelf lifeMfr#Part#AvailabilityPrice
Red6 months3170104.669 375In stockR 1,138.50
Red6 months3970504.669 377In stockR 33,775.50
Red6 months3970104.669 376In stockR 8,020.10
Red6 months3970086.318 227In stockR 6,755.10
Red6 months3971004.683 899R 47,285.70

Compare similar models

SafetyCap VI, V2.0, GL45 with 6x shut-off, 6x PFA-fitting 3,2 mm OD + air valve

Manufacturer P/N

307519

Part Number

9.139 804

Manufacturer

SCAT

Capillary connections

6

SafetyCap III, V2.0, GL45 with 3x shut-off, 3x PFA-fitting 3,2 mm OD + air valve

Manufacturer P/N

307920

Part Number

9.139 808

Manufacturer

SCAT

Capillary connections

3

SafetyCap IV, V2.0, GL45
Available soon
SCAT SafetyCap IV, V2.0, GL45

R 5,338.30

Inc. VAT

Manufacturer P/N

307419

Part Number

4.680 965

Manufacturer

SCAT

Capillary connections

4

SafetyCap II, V2.0 GL45, with shut-off (combined), 2x PFA-fitting 3,2 mm OD + air valve

Manufacturer P/N

307219

Part Number

9.139 899

Manufacturer

SCAT

Capillary connections

2

SafetyCap II, V2.0, GL45 with 2x shut-off, 2x PFA-fitting 3,2 mm OD + air valve

Manufacturer P/N

307919

Part Number

9.139 807

Manufacturer

SCAT

Capillary connections

2

SafetyCap III, V2.0, GL45 with 2x shut-off (combined), 3x PFA-fitting 3,2 mm OD + air valve

Manufacturer P/N

307319

Part Number

9.139 802

Manufacturer

SCAT

Capillary connections

3

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

1 min read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

1 min read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

1 min read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story

R 8,197.20

Inc. VAT