Representative Image

SCAT SafetyWasteCap V2.0 S60/61

Brand:SCAT

Capillary connections

No. of fittings

Thread

No. of blind plugs

Specifications

Compare models
Capillary connections
3
Connection for exhaust filter
1
Material
PTFE
No. of blind plugs
2
No. of fittings
3 x 2,3/3,2 mm
Thread
S 60/61
UNSPSC
41115700

R 8,551.40

Inc. VAT

Available soon

Product description

The SCAT SafetyWasteCap V2.0 S60/61 offers a safe and efficient solution for solvent waste disposal in laboratories. Designed with precision, this cap fits S60/61 container threads, ensuring a secure, leak-proof seal that prevents hazardous vapors from escaping. Its robust construction supports electrostatic safety and chemical resistance, making it ideal for handling aggressive substances in regulated environments. The SafetyWasteCap system supports a clean, closed waste handling process, minimizing exposure risks and improving overall lab safety and compliance.

Key Features:

  • Brand: SCAT
  • Model: SafetyWasteCap V2.0
  • Thread Compatibility: S60/61
  • Safety: Prevents vapor release and provides secure waste sealing
  • Material: High chemical resistance, electrostatically safe design
  • Application: Ideal for safe solvent disposal in laboratory environments

The SCAT SafetyWasteCap V2.0 S60/61 is a trusted choice for laboratories seeking a closed waste system to enhance safety and maintain compliance with solvent handling protocols.

Downloads

Accessories

Thread adapters for SafetyCaps / SafetyWasteCaps, female / male thread

ProductMaterialColourMfr#Part#AvailabilityPrice
PPColourless1070994.005 483In stockR 2,277.00
PTFEWhite1079929.139 882R 2,960.10
PTFEWhite1079919.139 883R 2,960.10
PTFEWhite1079934.005 639R 2,960.10
PPColourless1079954.005 641R 2,277.00
PPColourless1079964.005 642R 2,277.00
PPColourless1079944.005 640R 2,277.00
PPColourless1070934.005 477R 2,277.00
PPColourless1070794.005 463R 4,098.60
PPColourless1070904.005 474R 2,277.00
PPColourless1070284.005 433R 2,277.00
PTFEWhite1170304.005 789R 2,960.10
PPColourless1070954.005 479R 2,277.00
PPColourless1070924.005 476R 2,277.00
PTFEWhite1070724.005 456R 4,098.60
PPColourless1070944.005 478R 1,366.20
PPColourless1070864.005 470R 2,277.00
PPColourless1070974.005 481R 2,960.10
PPColourless1070744.005 458R 3,187.80
PPColourless1070854.005 469R 2,277.00
PPColourless1070894.005 473R 2,277.00
PPColourless1070914.005 475R 1,821.60
PPColourless1070964.005 480R 2,277.00
PPColourless1070714.005 950R 2,277.00
PPColourless1070844.005 468R 2,960.10

Compare similar models

SafetyWasteCap, V2.0, S60/61
Available soon
SCAT SafetyWasteCap V2.0 S60/61

R 8,551.40

Inc. VAT

Manufacturer P/N

307961

Part Number

4.680 967

Manufacturer

SCAT

Capillary connections

3

SafetyWasteCap S55 with mechanical level control, 2x3.2mm OD, 1x6.4mm ID (Leak)

Manufacturer P/N

107963

Part Number

4.005 612

Manufacturer

SCAT

Capillary connections

2

SafetyWasteCap S55 with mechanical level control, 3x3.2mm OD

Manufacturer P/N

107960

Part Number

4.005 609

Manufacturer

SCAT

Capillary connections

3

SafetyWasteCap S65 with mechanical level control, 3x3.2mm OD, 1x6.4mm ID (Leak)

Manufacturer P/N

107969

Part Number

4.005 618

Manufacturer

SCAT

Capillary connections

4

SafetyWasteCap S90 with mechanical level control, 4x3.2mm OD, 1x6.4mm ID (Leak)

Manufacturer P/N

107967

Part Number

4.005 616

Manufacturer

SCAT

Capillary connections

4

SafetyWasteCap S90 with mechanical level control, 4x3.2mm OD

Manufacturer P/N

107966

Part Number

4.005 615

Manufacturer

SCAT

Capillary connections

4

SafetyWasteCap B83 4x2.3/3.2mm OD, 1x6.4mm ID (Leak) with level control

Manufacturer P/N

108156

Part Number

4.005 717

Manufacturer

SCAT

Capillary connections

4

SafetyWasteCap, V2.0, S60/61 mechanical level control, 2x 2,3/3,2 mm OD, 1x 6,4 - 9 mm ID + connector for exhaust filter

Manufacturer P/N

307964

Part Number

6.316 823

Manufacturer

SCAT

Capillary connections

2

Frequently asked questions

It offers a safe and efficient solution for solvent waste disposal in laboratories. Designed with precision, this cap fits S60/61 container threads, ensuring a secure, leak-proof seal that prevents hazardous vapors from escaping. Its robust construction supports electrostatic safety and chemical resistance, making it ideal for handling aggressive substances in regulated environments. The SafetyWasteCap system supports a clean, closed waste handling process, minimizing exposure risks and improving overall lab safety and compliance.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

14 mins read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story

R 8,551.40

Inc. VAT