SI Analytics Viscometer Ubbelohde 530 10, Not Calibrated, for Automatic Measurement Capillary No. I, Constant K = 0.01

Constant

Int. Ø

Max. measured value

Measured range

Min. measured value

No. of capillary

Type

Specifications

Compare models
HS Code #
90278990
Calibration
No
Capacity
15 ... 20 ml
Constant
0.01
Int. Ø
0.63 mm
Length
290 mm
Max. measured value
10 mm²/s
Measured range
1.2 ... 10 mm²/s
Min. measured value
1.2 mm²/s
No. of capillary
I
Standard
ISO 3105, DIN 51562

R 10 600,70

Inc. VAT

Available soon

Product description

The SI Analytics Viscometer Ubbelohde 530 10 is designed for automatic viscosity measurements using capillary No. I. With a constant K = 0.01, this viscometer is ideal for applications where precise viscosity testing is needed. Though it is not calibrated, it provides the necessary functionality for labs conducting automatic measurements and can be calibrated according to the user's specific requirements.

Key Features:

  • Brand: SI Analytics
  • Type: Ubbelohde 530 10 for automatic measurement
  • Capillary: Capillary No. I for accurate fluid measurement
  • Constant: K = 0.01 for consistent viscosity testing
  • Calibration: Not calibrated, allows for customized calibration
  • Application: Ideal for viscosity testing in research and industrial applications

This SI Analytics Viscometer is an essential tool for laboratories requiring flexible viscosity measurement solutions, with the option for calibration based on specific needs.

Downloads

Accessories

Viscometer holders

ProductTypeMaterialMfr#Part#AvailabilityPrice
053 92Stainless steel2854050439.268 790R 8 728,50

Viscometer heating jacket

ProductTypeDescriptionMfr#Part#AvailabilityPrice
577 00Viscometer heating jacket2854055089.269 420R 25 553,00

Compare similar models

Viscometer Ubbelohde 530 10, not calibrated, for automatic measurement capillary no. I, constant K = 0.01

Manufacturer P/N

285400329

Part Number

9.268 310

Manufacturer

SI Analytics

Constant

0.01

Viscometer,Ubbelohde,ISO/DIN 3105,manual/automatic

Manufacturer P/N

285400312

Part Number

9.268 301

Manufacturer

SI Analytics

Constant

0.005

Viscometer,Ubbelohde,ISO/DIN 3105,manual/automatic constant 0,003 K,meas.range 0,5 - 3 mm²/sec

Manufacturer P/N

285400304

Part Number

9.268 303

Manufacturer

SI Analytics

Constant

0.003

Viscometer Ubbelohde 530 13, not calibrated, for automatic measurement capillary no. Ic, constant K = 0.03

Manufacturer P/N

285400337

Part Number

9.268 313

Manufacturer

SI Analytics

Constant

0.03

Viscometer,Ubbelohde,ISO/DIN 3105,manual/automatic constant 0,1 K,meas.range 10 - 100 mm²/sec

Manufacturer P/N

285400345

Part Number

9.268 320

Manufacturer

SI Analytics

Constant

0.1

Viscometer,Ubbelohde,ISO/DIN 3105,manual/automatic constant 0,3 K,meas.range 30 - 300 mm²/sec

Manufacturer P/N

285400353

Part Number

9.268 323

Manufacturer

SI Analytics

Constant

0.3

Viscometer Ubbelohde 530 40, not calibrated, for automatic measurement capillary no. IV, constant K = 10

Manufacturer P/N

285400386

Part Number

9.268 340

Manufacturer

SI Analytics

Constant

10

Viscometer Ubbelohde 530 33, not calibrated, for automatic measurement capillary no. IIIc, constant K = 3

Manufacturer P/N

285400378

Part Number

9.268 333

Manufacturer

SI Analytics

Constant

3

Viscometer Ubbelohde 530 30, not calibrated, for automatic measurement capillary no. III, constant K = 1

Manufacturer P/N

285400361

Part Number

9.268 330

Manufacturer

SI Analytics

Constant

1

Ubbelohde viscometer 53 011 (DIN) Not calibrated Capillary No. Ia, Constant K = 0.05

Manufacturer P/N

285400338

Part Number

7.984 645

Manufacturer

SI Analytics

Constant

0.05

Ubbelohde viscometer 530 21 (DIN), not calibrated

Manufacturer P/N

285400350

Part Number

6.521 031

Manufacturer

SI Analytics

Constant

0.5

Ubbelohde viscometer 530 31 Not calibrated

Manufacturer P/N

285400370

Part Number

4.711 075

Manufacturer

SI Analytics

Constant

5

More items to explore

Viscometers Ubbelohde, glass, kinematic

ProductTypeType of capillary viscometerMfr#Part#AvailabilityPrice
501 10Ubbelohde2854000379.268 110In stockR 16 773,90
501 20Ubbelohde2854000619.268 120In stockR 16 773,90
501 13Ubbelohde2854000459.268 113In stockR 16 773,90
501 00Ubbelohde2854000049.268 100R 17 381,10
501 01Ubbelohde2854000299.268 101R 16 773,90
532 11Ubbelohde2854001727.023 177R 16 773,90
501 30Ubbelohde2854000949.268 130R 16 773,90
501 21Ubbelohde2854000869.268 121R 16 773,90
501 31Ubbelohde2854001159.268 131R 16 773,90
501 23Ubbelohde2854000789.268 123R 16 773,90
532 10Ubbelohde2854002269.268 210R 16 773,90
501 03Ubbelohde2854000129.268 103R 16 773,90
532 21Ubbelohde2854001897.023 178R 16 773,90
532 31Ubbelohde2854001977.023 179R 16 773,90
532 40Ubbelohde2854002839.268 240R 16 773,90
532 30Ubbelohde2854002679.268 230R 16 773,90
532 03Ubbelohde2854002019.268 203R 16 773,90
532 13Ubbelohde2854002349.268 213R 16 773,90
532 00Ubbelohde2854001647.023 176R 17 381,10
501 11Ubbelohde2854000539.268 111R 16 773,90
532 23Ubbelohde2854002599.268 223R 16 773,90
501 40Ubbelohde2854001239.268 140R 16 773,90
501 33Ubbelohde2854001079.268 133R 16 773,90
532 20Ubbelohde2854002429.268 220R 16 773,90
532 01Ubbelohde2854002189.268 201R 16 773,90
532 33Ubbelohde2854002759.268 233R 16 773,90

Frequently asked questions

It is designed for automatic viscosity measurements using capillary No. I. With a constant K = 0.01, this viscometer is ideal for applications where precise viscosity testing is needed. Though it is not calibrated, it provides the necessary functionality for labs conducting automatic measurements and can be calibrated according to the user's specific requirements.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

14 mins read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story