Representative Image

Trajan Scientific Capillary Column GC HT5, 0.25mm ID x 0.1 µm x 30 m length

Film thickness

Int. Ø

Length

Specifications

Compare models
Film thickness
0.10 µm
Int. Ø
0.25 mm
Length
30 m
Max. temperature programme
400 °C
Temperature max. isotherm
380 °C
UNSPSC
41115710

R 24,414.50

Inc. VAT

Available soon

Product description

The Trajan Scientific Capillary Column GC HT5, 0.25mm ID x 0.1 µm x 30 m length is engineered for high-performance gas chromatography applications. Featuring a unique stationary phase of 5% phenyl polycarborane-siloxane, this column offers ultra-high temperature stability, making it ideal for analyzing a wide range of compounds including hydrocarbons, pesticides, herbicides, and for GC-MS applications. Its robust construction ensures reliable performance in GC-MS systems.

Key Features:

  • Brand: Trajan Scientific
  • Stationary Phase: 5% phenyl polycarborane-siloxane
  • Inner Diameter: 0.25 mm
  • Film Thickness: 0.1 µm
  • Length: 30 m
  • Temperature Range: 10°C to 380/400°C
  • Applications: Suitable for GC-MS analysis of hydrocarbons, pesticides, herbicides, and other volatile compounds

This capillary column is an essential tool for laboratories requiring precise and reliable chromatographic separations.

Downloads

Compare similar models

Capillary column GC HT5 0,25mm ID x 0,1µm x 30m length

Manufacturer P/N

054634

Part Number

4.682 428

Manufacturer

Trajan Scientific

Film thickness

0.10 µm

Capillary column HT5 15 m x 0.25 mm ID, Film thickness 0.1 µm

Manufacturer P/N

054633

Part Number

6.205 471

Manufacturer

Trajan Scientific

Film thickness

0.10 µm

Capillary column HT5 12 m x 0,32 mm ID, film thickness 0,1 µm

Manufacturer P/N

054641

Part Number

6.234 302

Manufacturer

Trajan Scientific

Film thickness

0.10 µm

Capillary Column HT5 25 m x 0,22 mm ID, Film Thickness 0,1 µm

Manufacturer P/N

054632

Part Number

4.667 654

Manufacturer

Trajan Scientific

Film thickness

0.10 µm

Capillary column GC HT5 0,22mm ID x 0,1µm x 12m length

Manufacturer P/N

054631

Part Number

4.682 427

Manufacturer

Trajan Scientific

Film thickness

0.10 µm

Capillary column GC HT5 0,22mm ID x 0,1µm x 50m length

Manufacturer P/N

054638

Part Number

4.682 429

Manufacturer

Trajan Scientific

Film thickness

0.10 µm

Capillary column GC HT5 0,53mm ID x 0,1µm x 6m length

Manufacturer P/N

054655

Part Number

4.682 430

Manufacturer

Trajan Scientific

Film thickness

0.10 µm

Capillary column GC HT5 0,53mm ID x 0,15µm x 12m length

Manufacturer P/N

054657

Part Number

4.682 431

Manufacturer

Trajan Scientific

Film thickness

0.15 µm

Capillary column GC HT5 0,53mm ID x 0,15µm x 25m length

Manufacturer P/N

054658

Part Number

4.682 432

Manufacturer

Trajan Scientific

Film thickness

0.15 µm

Capillary column GC HT5 0,32mm ID x 0,5µm x 15m length

Manufacturer P/N

054667

Part Number

4.682 433

Manufacturer

Trajan Scientific

Film thickness

0.50 µm

Capillary column HT5 25 m x 0,32 mm ID, film thickness 0,1 µm

Manufacturer P/N

054642

Part Number

7.911 177

Manufacturer

Trajan Scientific

Film thickness

0.10 µm

Frequently asked questions

It is engineered for high-performance gas chromatography applications. Featuring a unique stationary phase of 5% phenyl polycarborane-siloxane, this column offers ultra-high temperature stability, making it ideal for analyzing a wide range of compounds including hydrocarbons, pesticides, herbicides, and for GC-MS applications. Its robust construction ensures reliable performance in GC-MS systems.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

1 min read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

1 min read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

1 min read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story

R 24,414.50

Inc. VAT