Representative Image

Vacuubrand ME 4C NT Chemistry Diaphragm Pump, One-Stage, 230 V / 50 Hz, with CH Plug

Plug type

Specifications

Compare models
Depth
254 mm
Dimensions (WxDxH)
243 x 254 x 198 mm
Flow rate
3.9 m³/h
Height
198 mm
No. of stages
1
Plug type
CH
Type
ME 4C NT
Ultimate vacuum
70 mbar
UNSPSC
40151502
Width
243 mm

Alternative in-stock items

R 73,597.70

Inc. VAT

Available soon

Product description

The Vacuubrand ME 4C NT is a high-performance, single-stage diaphragm pump designed for continuous, oil-free evacuation and pumping of corrosive gases and vapors in laboratory settings. Operating at 230 V with a frequency of 50 Hz, this pump comes equipped with a CH plug for seamless integration into your laboratory infrastructure.

Key Features:

  • Brand: Vacuubrand
  • Type: Single-stage diaphragm pump for high-performance vacuum generation
  • Voltage: 230 V
  • Frequency: 50 Hz
  • Plug Type: CH plug for easy connection
  • Ultimate Vacuum: 70 mbar (52 torr)
  • Max. Pumping Speed at 50 Hz: 3.9 m³/h
  • Number of Heads: 2
  • Number of Stages: 1
  • Inlet Connection: Hose nozzle DN 8–10 mm
  • Outlet Connection: Hose nozzle DN 8–10 mm
  • Rated Motor Power: 0.18 kW
  • Rated Motor Speed at 50 Hz: 1500 min⁻¹
  • Protection Class (IEC 60529): IP 40
  • Dimensions (L x W x H): 254 mm x 243 mm x 198 mm
  • Weight: 11.1 kg
  • Noise Level: 45 dBA
  • ATEX Conformity: II 3G IIC T3 X (Internal Atm. only)

This diaphragm pump is an essential tool for laboratories that require a dependable, efficient vacuum pump for a wide range of chemical and sample processing applications. Its robust construction and high chemical resistance make it suitable for demanding environments.

Accessories

Sealing kit NT for chemistry diaphragm pumps NT

ProductForUNSPSCMfr#Part#AvailabilityPrice
MZ 2C NT40151502206968696.241 476R 7,615.30
MD 4C NT40151502206968706.239 489R 14,522.20
ME 4 NT, MZ 2 NT40151502206968609.880 902R 4,604.60
ME 4C NT40151502206968649.880 906R 4,427.50
MZ 2D NT40151502206968639.880 904R 4,604.60
MV 2 NT / MD 4 NT40151502206968619.880 905R 7,362.30
ME 8 NT40151502206968629.880 903R 6,072.00
ME 8C NT40151502206968679.880 907R 8,602.00

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081R 2,150.50
PVC34.9 mm206860634.714 084R 5,717.80
PVC38.1 mm206860654.714 085R 6,653.90
PVC15.9 mm206860614.714 082R 2,504.70
PVC22.3 mm206860624.714 083R 3,466.10

Compare similar models

Chemistry diaphragm pump ME 4C NT one-stage, 230 V~ 50 Hz plug CH

Manufacturer P/N

20731201

Part Number

9.880 895

Manufacturer

VACUUBRAND​

Plug type

CH

Chemistry diaphragm pump ME 4C NT one-stage, 230 V~ 50 Hz plug CEE

Manufacturer P/N

20731200

Part Number

9.880 894

Manufacturer

VACUUBRAND​

Plug type

EU

Chemistry diaphragm pump ME 4C NT, one stage, certification (NRTL): C/US230 V / 50-60 Hz, UK/IN mains cable

Manufacturer P/N

20731202

Part Number

4.670 425

Manufacturer

VACUUBRAND​

Plug type

UK

Chemistry diaphragm pump ME 4C NT, one stage, certification: (NRTL): C/US100-115 V / 50-60 Hz, 120 V / 60 Hz, US mains cable

Manufacturer P/N

20731203

Part Number

4.670 426

Manufacturer

VACUUBRAND​

Plug type

US

More items to explore

Diaphragm pumps chemistry design, ME 1C

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUME 1C207211009.880 934In stockR 31,852.70
UKME 1C207211029.880 936R 31,852.70
CHME 1C207211019.880 935R 31,852.70
USME 1C207211039.880 937R 31,852.70

Frequently asked questions

It is a high-performance, single-stage diaphragm pump designed for continuous, oil-free evacuation and pumping of corrosive gases and vapors in laboratory settings. Operating at 230 V with a frequency of 50 Hz, this pump comes equipped with a CH plug for seamless integration into your laboratory infrastructure.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

1 min read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

1 min read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

1 min read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story

R 73,597.70

Inc. VAT