Representative Image

Ludwig Schneider Sensor w. Tip, Type K w. Handle (NiCr-Ni) w/ Miniature Connector, Yellow, Length 150 mm, Sheath Ø 3 mm, Application Range -100...+200 °C

Ø

Dimensions (ØxL)

Length

Max. temperature

Min. temperature

Sort of probe

Temperature

Specifications

Compare models
Cable length
2 m
Ø
3 mm
Dimensions (ØxL)
3 x 150 mm
Length
150 mm
Max. temperature
200 °C
Min. temperature
-100 °C
Sort of probe
Insertion probe
Temperature
-100 ... 200 °C
Type of probe
Type K
UNSPSC
41112219

R 5,464.80

Inc. VAT

Available soon

Product description

The Ludwig Schneider Sensor with Tip, Type K with Handle (NiCr-Ni) is a versatile temperature sensor designed for precise temperature measurements across a range of -100 °C to +200 °C. The sensor features a miniature connector and a yellow handle for easy identification. With a sheath diameter of 3 mm and a length of 150 mm, it is ideal for applications requiring accurate and reliable temperature monitoring in laboratory and industrial environments.

Key Features:

  • Brand: Ludwig Schneider
  • Type: Type K temperature sensor with NiCr-Ni thermocouple
  • Handle: Includes ergonomic handle for ease of use
  • Connector: Miniature connector, yellow color for easy identification
  • Sheath Diameter: Ø 3 mm
  • Length: 150 mm
  • Temperature Range: -100 °C to +200 °C
  • Application: Suitable for precise temperature monitoring in labs and industrial environments

This high-performance sensor from Ludwig Schneider ensures reliable and accurate temperature measurements for a wide range of applications.

Compare similar models

Sensor w.tip, type K w. handle (NICR-NI) w/ miniature connector yellow, length 150mm sheath ø 3 mm, application range -100...+200°C

Manufacturer P/N

71120

Part Number

6.313 326

Manufacturer

Ludwig Schneider

Ø

3 mm

Penetration probe, with handle, type K, -50 ... 600 °C, class 2, to DIN EN 60584, for type 13100

Manufacturer P/N

65861

Part Number

9.236 717

Manufacturer

Ludwig Schneider

Ø

3.8 mm

Sensor w.tip, type K w. handle (NICR-NI) w/ miniature connector yellow, length 250mm sheath ø 3 mm, application range -100...+250°C

Manufacturer P/N

71121

Part Number

6.313 325

Manufacturer

Ludwig Schneider

Ø

3 mm

Sensor type K with handle (NICR-NI) w/ miniature connector yellow,nominal length 400mm sheath ø 3 mm, application range -100...+800°C

Manufacturer P/N

71119

Part Number

6.313 327

Manufacturer

Ludwig Schneider

Ø

3 mm

mmersion sensor type K with handle 150 x 3 mm, with flat plug, -100...+200°C,±2,5°C according to DIN EN 60584 class 2, for type 13100,

Manufacturer P/N

65859

Part Number

6.313 063

Manufacturer

Ludwig Schneider

Ø

3 mm

Sensor w. tip, type K w. handle (NICR-NI) w/ miniature connector yellow, length 400mm sheath ø 3 mm, application range -100...+250°C

Manufacturer P/N

71122

Part Number

6.313 324

Manufacturer

Ludwig Schneider

Ø

3 mm

Sensor type K with handle (NICR-NI) w/ miniature connector yellow,nominal length 250mm sheath ø 3 mm, application range -100...+400°C

Manufacturer P/N

66269

Part Number

6.313 328

Manufacturer

Ludwig Schneider

Ø

3 mm

Frequently asked questions

It is a versatile temperature sensor designed for precise temperature measurements across a range of -100 °C to +200 °C. The sensor features a miniature connector and a yellow handle for easy identification. With a sheath diameter of 3 mm and a length of 150 mm, it is ideal for applications requiring accurate and reliable temperature monitoring in laboratory and industrial environments.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

11 mins read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

14 mins read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

10 mins read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story

R 5,464.80

Inc. VAT