Representative Image

Vacuubrand Diaphragm Pump MZ 2D NT, Two-Stage, Certification (NRTL): C/US, 230 V / 50-60 Hz, UK/IN Mains Cable

Plug type

Specifications

Compare models
Connection pressure side
G1/4"
Connection suction side
KF DN 16
Depth
246 mm
Dimensions (WxDxH)
242 x 246 x 198 mm
Flow rate
2.3 m³/h
Height
198 mm
No. of stages
2
Plug type
UK
Type
MZ 2D NT
Type of auxiliary energy
Mains connection

R 68,259.40

Inc. VAT

Available soon

Product description

The Vacuubrand Diaphragm Pump MZ 2D NT is a high-performance, oil-free vacuum pump designed for continuous operation in laboratory and industrial settings. With its two-stage design and NRTL C/US certification, it ensures safety and compliance for various applications. Operating at 230 V / 50-60 Hz and equipped with a UK/IN mains cable, this pump offers versatility and convenience.

Key Features:

  • Brand: Vacuubrand
  • Model: MZ 2D NT
  • Design: Two-stage diaphragm pump
  • Certification: NRTL C/US
  • Voltage: 230 V / 50-60 Hz
  • Power Cord: UK/IN mains cable
  • Flow Rate: 2.3 m³/h (50 Hz)
  • Ultimate Vacuum: 4 mbar
  • Noise Level: Whisper-quiet operation
  • Dimensions (W x D x H): 239 x 328 x 198 mm
  • Weight: 16.4 kg
  • Inlet Connection: Small flange KF DN 16
  • Outlet Connection: Silencer / G1/4"

This pump is ideal for applications requiring reliable and quiet vacuum performance, such as vacuum ovens, filtration processes, and general laboratory use. Its robust construction and low maintenance design make it a valuable addition to any lab.



Frequently Asked Questions

1. What is the Vacuubrand Diaphragm Pump MZ 2D NT, Two-Stage, Certification: C/US, 230 V / 50-60 Hz, UK/IN Mains Cable used for?

It is a high-performance, oil-free vacuum pump designed for continuous operation in laboratory and industrial settings. With its two-stage design and NRTL C/US certification, it ensures safety and compliance for various applications. Operating at 230 V / 50-60 Hz and equipped with a UK/IN mains cable, this pump offers versatility and convenience.

2. Is this product suitable for continuous operation in laboratory and industrial settings?

Yes. It is designed for continuous operation in laboratory and industrial settings, and offers a voltage of 230 V / 50-60 Hz and a flow rate of 2.3 m³/h (50 Hz) to support this kind of work.

3. What voltage and flow rate does this product have?

It has a voltage of 230 V / 50-60 Hz, a flow rate of 2.3 m³/h (50 Hz) and an ultimate vacuum of 4 mbar.

4. What design and certification does this product offer?

It offers two-stage diaphragm pump, NRTL C/US, UK/IN mains cable and whisper-quiet operation.

Downloads

Accessories

Sealing kit NT for chemistry diaphragm pumps NT

ProductForUNSPSCMfr#Part#AvailabilityPrice
MZ 2C NT40151502206968696.241 476R 7,615.30
MD 4C NT40151502206968706.239 489R 14,522.20
ME 4 NT, MZ 2 NT40151502206968609.880 902R 4,604.60
ME 4C NT40151502206968649.880 906R 4,427.50
MZ 2D NT40151502206968639.880 904R 4,604.60
MV 2 NT / MD 4 NT40151502206968619.880 905R 7,362.30
ME 8 NT40151502206968629.880 903R 6,072.00
ME 8C NT40151502206968679.880 907R 8,602.00

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081R 2,150.50
PVC34.9 mm206860634.714 084R 5,717.80
PVC38.1 mm206860654.714 085R 6,653.90
PVC15.9 mm206860614.714 082R 2,504.70
PVC22.3 mm206860624.714 083R 3,466.10

Compare similar models

Diaphragm pump MZ 2D NT, two stage, certification (NRTL): C/US230 V / 50-60 Hz, UK/IN mains cable

Manufacturer P/N

20732202

Part Number

4.670 432

Manufacturer

VACUUBRAND​

Plug type

UK

Diaphragm pump MZ 2D NT two-stage, 230 V~ 50 Hz plug CEE

Manufacturer P/N

20732200

Part Number

9.880 889

Manufacturer

VACUUBRAND​

Plug type

EU

Diaphragm pump MZ 2D NT, two stage, certification (NRTL): C/US100-115 V/50-60 V, 120 V/60 Hz, US mains cable

Manufacturer P/N

20732203

Part Number

4.670 433

Manufacturer

VACUUBRAND​

Plug type

US

More items to explore

Diaphragm pumps, Aluminium PTFE design, ME 1

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUME 1207210009.880 930R 23,807.30
UKME 1207210029.880 932R 23,807.30
CHME 1207210019.880 931R 23,807.30
USME 1207210039.880 933R 23,807.30

Frequently asked questions

It is a high-performance, oil-free vacuum pump designed for continuous operation in laboratory and industrial settings. With its two-stage design and NRTL C/US certification, it ensures safety and compliance for various applications. Operating at 230 V / 50-60 Hz and equipped with a UK/IN mains cable, this pump offers versatility and convenience.

Insights

Explore
What is a Laboratory Desiccator? Uses, Types and How It Works

1 min read

What is a Laboratory Desiccator? Uses, Types and How It Works

A laboratory desiccator keeps its contents in a dry, low-humidity atmosphere, protecting hygroscopic reagents and moisture-sensitive samples and cooling heated samples for accurate weighing. This guide covers what it is, what it is used for, the main types, the desiccants that go inside, and how it works, with an animated drying cycle and a setup finder.

Read full story
What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

1 min read

What is a Buchner Funnel? Uses, Setup and How Vacuum Filtration Works

The Buchner funnel is the standard tool for fast vacuum filtration across South African labs, from minerals and assay work to SANAS-accredited QC. This guide covers what it is, what it is used for, how to set one up step by step, the main materials, and how vacuum filtration works, with an animated apparatus and a funnel finder.

Read full story
What is a Separating Funnel? Uses and How It Works

1 min read

What is a Separating Funnel? Uses and How It Works

A separating funnel parts two immiscible liquids by density and is central to liquid-liquid extraction, from minerals and assay work to environmental testing and SANAS-accredited QC. This guide walks through what it is, how it works step by step, the pear-shaped and conical types, and how to choose one, with an animated demo and funnel finder.

Read full story

R 68,259.40

Inc. VAT